Name: NitriSkin Sterile Singles, Powder-Free Nitrile Exam Gloves (MGSE502)


Uses:Latex Powder FreeIdeal for sterile clinical procedures when an exceptionally resistant latex-free glove is required. It is designed as an alternative for individuals who may have a Type 1 hypersensitivity to natural rubber latex proteins. Our textured gloves enhance grip in wet and dry environments. The NitriSkin Sterile Singles glove is a high-performing, latex-free exam glove for use in every application in a healthcare environment. Exceptionally stretchy soft, low modulus nitrile synthetic compound is very comfortable for extended periods.

NitriSkin Sterile Singles are now the ultimate choice use of medical professionals in high demand environments like Obstetricians and Gynecologists, intensive care unit ICC/CCU, traumas, burn centers and wound care that requires a high quality latex-free sterile glove that delivers maximum barrier protection.

Approved for use with Chemotherapy drugs*


Special Features:Powder Free minimizes the risk of developing latex protein or chemical residue related allergies. Eliminate powder related contamination in critical exam or in clean room environment. Our ambidextrous sterile latex-free exam gloves features excellent tactile sensitivity and stretchy to provide a sure grip. Tested for use with Chemotherapy drugs*
  • Sterile, Individually Wrapped
  • Powder-Free
  • Latex Free
  • Ambidextrous
  • Sizes are S, M, L & XL:

    S (size equivalent: 6 ½ - 7)
    M (size equivalent: 7 ½ - 8)
    L (size equivalent: 8 ½ - 9)
    XL (size equivalent: 9 ½ - 10)
    Specifications:
  • Length min. 9.5” (240mm)
  • Avg. Finger Thickness (mm) min. 0.20
  • Tensile Strength Before Aging min. 28 MPa
  • Tensile Strength After Aging min. 20 MPa
  • Elongation Before Aging (%) min. 900
  • Elongation After Aging (%) min. 880


Quantity:100/box, 4 boxes/case (1 case = 400 gloves). Gloves are ambidextrous (each glove fits either hand).
Quality:Meets or exceeds ASTM D6319. This glove meets the emergency medical glove requirements of NFPA 1999, standard on protective clothing for emergency medical operations, 2003 edition.


Other:This glove is for single use only.

Tested for Use With Chemotherapy Drugs
Test Chemical
Breakthrough Detection Time (Minutes)
Permeated Mass per unit area at Breakthrough
(Avg.), ug/cm²
Steady State
Permeation Rate
(Avg.), ug/cm²/min
Carmustine (BiCNU)
3,300 ppm
No breakthrough was
detected up to 240 mins.
0
0
Cisplatin
1,000 ppm
No breakthrough was
detected up to 240 mins.
0
0
Cyclophosphamide (Cytoxan)
20,000 ppm
No breakthrough was
detected up to 240 mins.
0
0

Dacarbazine (DTIC)
10,000 ppm

No breakthrough was
detected up to 240 mins.
0
0

Doxorubicin Hydrochloride
2,000 ppm

No breakthrough was
detected up to 240 mins.
0
0

Ethoposide
20,000 ppm

No breakthrough was
detected up to 240 mins.
0
0

5-Fluorouracil
50,000 ppm

No breakthrough was
detected up to 240 mins.
0
0

Paclitaxel (Taxol)
6,000 ppm

No breakthrough was
detected up to 240 mins.
0
0

Thio-Tepa
10,000 ppm

No breakthrough was
detected up to 240 mins.
0
0

Mitomycin
500 ppm

No breakthrough was
detected up to 240 mins.
0
0

Methotrexate
25,000 ppm

No breakthrough was
detected up to 240 mins.
0
0

Mitoxantrone
2,000 ppm

No breakthrough was
detected up to 240 mins.
0
0

50,000 ppm

No breakthrough was
detected up to 240 mins.
0
0

10,000 ppm

No breakthrough was
detected up to 240 mins.
0
0
  • Applies to all Nitrile sterile and non-sterile Exam and Surgical gloves.
  • For additional Chemical Resistance Data, please call: please call: 800-434-0012
  • Gloves used for protection against chemical exposure must be selected specifically for the type of chemicals used.
  • Review material safety data sheets for the chemicals being used to determine the required level of protection.
  • Additionally tested per ASTM F739 for use with chemo drugs, which can be especially damaging to a glove or cause a glove failure.